User`s manual
December 2003
9-12 Using the Ultrasonic Thickness Gage
Transducer Delay
This number represents the time the ultrasonic signal takes to
travel from the TransPort to the pipe material surface. This
number should be set to 7.0 microseconds unless otherwise
instructed by the factory. To change this number:
1. Use the numeric keys to enter the new number.
2. Press [ENT].
The TransPort proceeds to the next prompt.
System Units
System Units are identical to the system units in the Flowmeter
Program Menu; however, these system units apply to the
thickness gage. This is the only parameter you should change
without consulting the factory.
To change the System Units, use one of the following keys to
respond:
• Press [F1] for English units or
• Press [F2] for Metric units.
The TransPort automatically proceeds to the next prompt.
Gain Level
The gain level is set at the factory and should not need to be reset;
however, if you are instructed to change the gain level:
• Press [F1] for Low Gain or
• Press [F2] for High Gain.