User manual

Page 9 of 14 Ethernet Extension Experts
Unpacking the Enable-IT 868 PoE+ & Extended Ethernet Kit
Carefully remove the Enable-IT 868 PoE+ & Extended Ethernet Kit all packing materials
from the box. Verify that the items listed below are present. Make sure that the
equipment supplied matches what you ordered. If any items are missing or damaged,
please contact Enable-IT or your distributor for assistance.
(2) The Enable-IT 868 PoE+ & Extended Ethernet Units (CO & CPE)
o 5v AC/DC Power adapter for 868 CO
o 10’ LAN patch cables
o Enable-IT 360 60W -56v High PoE+ Injector
(1) Enable-IT 868 PoE+ & Extended Ethernet Kit User Manual (this manual)
(1) Enable-IT 360 PoE+ Injector User Manual
Perform an out of the box Test
We highly recommend a quick test to ensure the working order of you 868 units.
To do this, please use one of the Ethernet patch cords provided and attach to the
868 Interlink port of each 868 unit. Using the 5v power adapter, power up the 868
CO Unit and attach the 360 PoE+ Injector (P+Data Out port) to the 868 CO
LAN1/PoE+ port. After a few seconds you should see a solid Green Interlink Sync
LED on each unit to confirm a link is established. The Green Interlink Sync LED
will pulse rapidly as it detects traffic. This confirms basic proper operation of the
units. Next for a more detailed test and to confirm your PoE+ LAN Equipment
works with the 868, connect your Ethernet LAN and PoE+ remote device to the 868
LAN ports and test connectivity.
WARNING: DO NOT
use LAN1/2 PoE+ port on the CPE end for non-PoE+ equipment
as it may damage any non-PoE+ equipment. Use the LAN 3-4 ports on the CPE for
non-PoE+ equipment.
LED indicators will provide visual operational status of the 868 units.
Sync - Slow to fast flicker on power up indicates negotiation of a link.
Solid Green LED indicates link established and rapid pulse is traffic.
Pwr - Solid Green LED indicates that unit is receiving 5v power.
Mode - Solid Yellow LED on CPE unit only No LED lit on CO
ACT - Yellow LEDs Lit solid indicates the presence of local LAN
Blinking indicates the presence of local LAN traffic
Next for a more detailed test and to confirm your PoE+ Equipment works with the
868, connect your PoE+ device to the 868 CPE LAN1/PoE+ port and your LAN to
the 360 PoE+ Injector Data IN port. For use with a Cisco PoE+ device such as
Aironet WiFi AP Use the provided Cisco PoE+ patch cord or build one using it as
a guide.