Datasheet

Module operation SP1ML
20/27 DocID026906 Rev 3
S18 BROADCAST_ADDR
Address: The 8-bit broadcast address, used for broadcast filtering on
received packets.
Values:
Any 8-bit hexadecimal value.
Default: 0xff
S19 FILTER_CRC
Address: Filter packets that have an invalid CRC.
Values:
0 = Disabled, 1 = Enabled
Default: 0
S20 FILTER_SOURCE
Address: Filter packets that do not have a source address that
matches the address specified in register S16.
Values:
0 = Disabled, 1 = Enabled
Default: 0
S21 FILTER_DESTINATION
Address: Filter packets that do not have a destination address that
matches the modules source address specified in register S15.
Values:
0 = Disabled, 1 = Enabled
Default:
0
S22 FILTER_MULTICAST
Address: Filter packets that do not have a destination address that
matches the multicast address in specified in register S17.
Values:
0 = Disabled, 1 = Enabled
Default: 0
S23 FILTER_BROADCAST
Address: Filter packets that do not have a destination address that
matches the broadcast address in specified in register S18.
Values:
0 = Disabled, 1 = Enabled
Default:
0
S24 TXRX_LED
General: Enable or disable the TX/RX LED output on module pin 1.
When enabled, the LED output will be flashed when data is sent or
received by the radio.
Values:
0 = Disabled, 1 = Active-Low Open Drain Output, 2 = Push Pull Output
Default:
0
S26 ESCAPE_SEQ
General: Enable or disable the ‘+++’ escape sequence used to enter
command mode. This configuration is never stored and will be enabled
at module reset.
Values:
0 = Disabled, 1 = Enabled
Default: 1
Table 10. Configuration registers (continued)