User manual
P a g e 9 o f 1 5 E t h e r n e t E x t e n s i o n E x p e r t s
Unpacking the Enable-IT 865 PoE & Extended Ethernet Kit
Carefully remove the Enable-IT 865 PoE & Extended Ethernet Kit all packing materials
from the box. Verify that the items listed below are present. Make sure that the
equipment supplied matches what you ordered. If any items are missing or damaged,
please contact Enable-IT or your distributor for assistance.
• (2) The Enable-IT 865 PoE & Extended Ethernet Units (CO & CPE)
o 5v AC/DC Power adapter for 865 CO
o LAN patch cables
o Enable-IT 350 48v PoE Injector for 865 CO
• (1) Enable-IT 865 PoE & Extended Ethernet Kit User Manual (this manual)
• (1) Enable-IT 350 PoE Injector User Manual
Perform an out of the box Test
We highly recommend a quick test to ensure the working order of you 865 units.
To do this, please use one of the Ethernet patch cords provided and attach to the
865 Interlink port of each 865 unit. Using the 5v power adapter, power up the 865
CO Unit and attach the 350 PoE Injector (P+Data Out port) to the 865 CO LAN1/PoE
port. After a few seconds you should see a solid Green Interlink Sync LED on
each unit. This confirms basic proper operation of the units.
W A R N I N G : D O N O T
u s e L A N 1 / P o E p o r t o n t h e C P E e n d f o r n o n -P o E e q u i p m e n t a s i t
m a y d a m a g e a n y n o n -P o E e q u i p m e n t . U s e t h e L A N 2 p o r t o n t h e C P E f o r n o n -P o E
e q u i p m e n t .
LED indicators will provide visual operational status of the 865 units.
Interlink Sync - Solid Green LED indicates that the 865 units see eachother.
Unit Pwr - Solid Green LED indicates that both units are receiving 5v power.
Unit Mode - Solid Yellow LED on CPE unit only – No LED lit on CO
LAN1 ACT - Yellow LED – Lit solid indicates the presence of local LAN
– Blinking indicates the presence of local LAN traffic
Next for a more detailed test and to confirm your PoE Equipment works with the
865, connect your PoE device to the 865 CPE LAN1/PoE port and your LAN to the
350 PoE Injector Data IN port. For use with a Cisco PoE device such as Aironet
WiFi AP – Use the provided Cisco PoE patch cord or build one using it as a guide.