User manual
P a g e 1 0 o f 1 5 E t h e r n e t E x t e n s i o n E x p e r t s
Performing the On-Site Installation
After removing the Enable-IT 865 PoE & Extended Ethernet Kit from the box and
performing the out of the box testing all that remains to install the unit on-site is to mount
the unit, build the interconnect wiring, add voice lines if needed and attach the LAN
device cabling with the provided Ethernet Patch cords.
Mounting the Enable-IT 865 PoE & Extended Ethernet Units
The Enable-IT 865 PoE & Extended Ethernet Kit is designed for quick wall mounting.
Choose a location to mount each of the Enable-IT 865’s where the maximum
distance does not exceed 2,500ft or 762m total between devices to be connected.
When mounting the Enable-IT 865 PoE & Extended Ethernet Kit it is recommended
that you use the appropriate anchors for your mounting surface. If mounting on
plywood use wood screws; if mounting onto drywall or sheetrock, use plastic drywall
anchors or Velcro can also be used as the units are very lightweight.
Building the 865 Interlink wiring
The most important aspect of the install is the correct wiring of the Interlink cabling.
For CAT3 wiring (3-pair/6wires) you will need to crimp a RJ-45 Male Head to each
end of the contiguous wire run and using the following pins(1,2,4,5,7 & 8) straight
through. This will deliver 1 Voice line, Ethernet Data and PoE. Insert into the Interlink
Port on each 865 unit.
For CAT5e or better wiring (4-pair/8wires) you will need to crimp a RJ-45 Male Head
to each end of the contiguous wire run and using the following pins(1,2,3,4,5,6,7 & 8)
straight through. This will deliver Dual Voice lines, Ethernet Data and PoE. Insert into
the Interlink Port on each 865 unit. This can be either T-568A or T-568B spec.
Attaching cabling and devices to the Enable-IT 865 Extended Ethernet Kit.
Attach your remote PoE device to the 865 CPE unit LAN1/PoE port with Ethernet
patch cord provided. Attach your local LAN to the 350 PoE injector Data IN port.
Attach the power adapter to the 865 CO unit. Attach the 350 PoE injector to the 865
CO LAN1/PoE port with Ethernet patch cord provided. Apply power to the 350 PoE
injector with the country power cord provided.
If you plan on using voice service as well, insert your dial tone voice line/lines to the
865 CO unit (Dual Voice – IN) RJ-11port and telephone handset to the 865 CPE unit
Dual Voice – OUT) RJ-11 port. Your equipment should now be powered up and
functioning properly. The LED indicators will provide visual operational status of the
865 units.
Interlink Sync - Solid Green LED indicates that the 865 units see eachother.
Unit Pwr - Solid Green LED indicates that both units are receiving 5v power.
Unit Mode - Solid Yellow LED on CPE unit only – No LED lit on CO
LAN1 ACT - Yellow LED – Lit solid indicates the presence of local LAN
– Blinking indicates the presence of local LAN traffic
8 6 5 C P E
8 6 5 C O