Cabling Devices to The Enable-IT 865 PRO Extended Ethernet Kit!
Attach your remote LAN device to the 865 PRO CPE unit LAN ports with Ethernet patch cord
provided. Attach your local LAN to the 865 PRO CO LAN ports with Ethernet patch cord
provided. Attach the power adapters to both 865 PRO units.
Attach your local Interlink cabling end to the 865 PRO CO unit Interlink port – Then do the same
for the remote end and plug into the 865 PRO CPE unit Interlink port. The Sync LED’s will
flicker in a sequence talking to each other until they go solid. Your equipment should now be
powered up and functioning.
LED indicators will provide visual operational status of the 865 PRO units.
Troubleshooting!
First examine the backbone wiring pair and make sure you have solid connections. The Interlink
Sync LED will be lit solid Green with rapid pulsing on each 865 PRO unit to show proper connection
and pairing. If the Interlink Sync LED Link is flashing slow to fast and never goes solid…. Then follow
the steps below:
1) Make sure your wiring is straight through and not connected to any Telco punch down
blocks; If so remove from the block and use Telco butt clips to bridge wire.!
2) Check for a firm connection of the RJ-45 connections in each 865 PRO unit, and power
is applied to the 865 PRO CO & CPE units.!
3) You can easily isolate any issue by performing an Out Of The Box Test (OOTBT). This
test will confirm the correct working order of your Enable-IT 865 PRO PoE Extender Kit.
This will point to a possible issue with your long distance Interlink wiring being
affected by possible outside interference.
!
Out Of The Box Test (OOTBT)
Using one of the Ethernet patch cords provided, attach it to the Interlink port of each 865
PRO unit. Using another Ethernet patch cord provided, attach it to the Data and Power
Out port of the 360 PoE Injector and the other end to the 865 PRO CO LAN port 1 port.
Attach the secure locking 12V DC adapter to the 865 PRO CO unit and power up the 360
PoE Injector and the 865 PRO CO. The Green Sync LEDs will start flickering slowly and
then fast as the units talk to each other. After a few seconds you should see a solid
Green Interlink Sync LED on each unit to confirm a link is established. This confirms
basic proper operation of the units. Next for a more detailed test and to confirm your
PoE end device Equipment works with the 865 PRO CPE, connect your Ethernet LAN and
remote device to the 865 PRO LAN 1 ports and test connectivity. The Green Interlink
Sync LED will pulse rapidly as it detects traffic
All Rights Reserved © 1997 - 2015 Enable-IT™, Inc. Page ! of !4 9