User manual

Page 8 of 14 Ethernet Extension Experts
I
NSTALLING THE 860C EXTENDED ETHERNET KIT
The Enable-IT 860C Extended Ethernet Units have a distance restriction of 6,000ft or
1,828m over 2-pair of Category 3 up to Category 5e / CAT6 wiring from device extension
to device extension. Therefore quick, simple site surveys and installation planning are
highly recommended.
This chapter describes the recommended installation process for the Enable-IT 860C
Extended Ethernet Unit. It covers the following topics:
Site Plan Installation Design Considerations
Unpacking the Enable-IT 860C Extended Ethernet Kits
Perform an out of the box Test
Performing the On-Site Installation
Site Plan - Installation Design Considerations
The planning process should involve a site walkthrough and discovery survey. Electrical
Cable measurement tools are the most reliable method to determine the longest run of
hidden wiring. Estimate the best locations to position the Broadband Concentrators to
adequately reach desired connectivity on each floor. Document your findings to use in
designing a network topology to support the Ethernet Switches and backbone
connectivity. Key points to remember in the Site Survey.
Total distance limitation of 6,000ft or 1,829m from end to end.
BNC Coaxial RG58/RG6 cabling, 2 Pair CAT-3 wiring, 4-pair Cat5e .30 Gage or
better cabling is required for the 860C Interlink transmission.
For the Interlink wiring you can use either RJ-45 or BNC Coaxial connectors. Crimp
a RJ-45 Male Head to each end of the contiguous wire run and using the following
pins (1 & 2) straight through. This will deliver 1 Voice line, Ethernet Data. If you
desire to use the second voice line, you can also use pins (3 & 6) on each end
straight through.
The 860C Interlink port (BNC Coax interface) carries this 2-pair signaling over the
RG58/RG6 pins (1, 2, 3 & 6) - used for transport for both voice and data. The
remaining pins 4, 5, 7 & 8 are can transport native PoE or are unused. BNC Coaxial
Interlink ports are provided for use with RG58/RG6 coaxial cabling.
860 CPE
860 CO