INSTALLING THE 860 PRO ETHERNET EXTENDER KIT
The Enable-IT 860 Pro Ethernet Extenders have a distance restriction of 6,000ft
(1,829m) over 1-pair of Category 2, up to 4-pair CAT5e / CAT7, wiring from device
extension to device extension. Therefore quick, simple site surveys and installation
planning are highly recommended.
This chapter describes the recommended installation process for the Enable-IT 860 Pro
Ethernet Extender Kit. The following topics are covered:
Site Plan – Installation Design Considerations
Unpacking the Enable-IT 860 Pro Ethernet Extender Kit
Perform an Out Of The Box Test (OOTBT)
Performing the On-Site Installation
Site Plan – Installation Design Considerations
The planning process should involve a site walk-through and discovery survey.
Electrical cable measurement tools are the most reliable method to determine the
longest run of hidden wiring. Estimate the best locations to position the Broadband
concentrators to adequately reach desired connectivity on each floor. Document your
findings to use in designing a network topology to support the Ethernet switches and
backbone connectivity. The following are key points to remember in the site survey:
Total distance limitation of 6,000ft (1,829m) from end-to-end.
1-Pair CAT2 wiring, or 4-pair CAT5e, .30 gauge, or better, cabling is required for
the 860 Pro Interlink transmission.
For the Interlink wiring you will need to use RJ-45 connectors. Crimp a RJ-45 Male head
to each end of the contiguous wire run and use pins 1 & 2 straight through. This will
deliver 1 voice line, and Ethernet data. If you desire to use the second voice line, you
can also use pins 3 & 6 on each end straight through.
The 860 Pro Interlink port (RJ-45) carries this 1-pair signaling over the RJ-45 pins (1 &
2) - used as transport for both voice and data. If you use more than 1-pair of wiring,
such as a CAT5 segment, the RJ-45 pins 3 & 4 are used for voice line 2, and the
remaining pins (4,5,7 & 8) can transport native 802.3af PoE, or are unused. As an
option, telephone dongles can be provided for use with existing RJ-11 wiring.
Optional Dongle:
RJ-45 Male Head: Pins 1 & 2 – Voice line 1 and data
Pins 3 & 6 – Voice line 2 and data
RJ-11 Sockets: Pins 2 & 3 – VDLS2 & Phone port – Voice line 1 and data
Pins 1 & 4 – Voice line 2