User manual
P a g e 9 o f 1 4 E t h e r n e t E x t e n s i o n E x p e r t s
Unpacking the Enable-IT 860 Extended Ethernet Kit
Carefully remove the Enable-IT 860 Extended Ethernet Kits all packing materials from
the box. Verify that the items listed below are present. Make sure that the equipment
supplied matches what you ordered. If any items are missing or damaged, please
contact Enable-IT or your distributor for assistance.
• (2) The Enable-IT 860 Extended Ethernet Units (CO & CPE)
o 5v AC/DC Power adapter
o LAN patch cables
• (1) Enable-IT 860 Extended Ethernet Kit User Manual (this manual)
Perform an out of the box Test
We highly recommend a quick test to ensure the working order of you 860 units.
To do this, please use one of the Ethernet patch cords provided and attach to the
860 Interlink port of each 860 unit. Power up both 860 units. After a few seconds
you should see a solid Green Interlink Sync LED on each unit. This confirms
basic proper operation of the units. Next for a more detailed test and to confirm
your LAN Equipment works with the 860, connect your Ethernet LAN and remote
device to the 860 LAN ports and test connectivity.
LED indicators will provide visual operational status of the 860 units.
Interlink Sync - Solid Green LED indicates that the 860 units see eachother.
Unit Pwr - Solid Green LED indicates that both units are receiving 5v power.
Unit Mode - Solid Yellow LED on CPE unit only – No LED lit on CO
LAN ACT - Yellow LED – Lit solid indicates the presence of local LAN
– Blinking indicates the presence of local LAN traffic
Performing the On-Site Installation
After removing the Enable-IT 860 Extended Ethernet Kit from the box and performing the
out of the box testing all that remains to install the unit on-site is to mount the unit, build
the interconnect wiring, add voice lines if needed and attach the LAN device cabling with
the provided Ethernet Patch cords.
Mounting the Enable-IT 860 Extended Ethernet Units
The Enable-IT 860 Extended Ethernet Kits are designed for quick wall mounting.
Choose a location to mount each of the Enable-IT 860’s where the maximum
distance does not exceed 6,000ft or 1,829m total between devices to be connected.
When wall-mounting the Enable-IT 860 Extended Ethernet Kit it is recommended that
you use the appropriate screw anchors for your mounting surface. If mounting on
existing plywood use wood screws; if mounting onto drywall or sheetrock, use plastic
drywall anchors to secure your installation.
8 6 0 C O