INSTALLING THE SD17063
ADVANCED MICRO CONTROLS INC.
5
32
Step 1: Installing the Drive (continued)
Dimensional Drawing (continued)
Figure 5.1 SD17063 Mounting Dimensions
+
STEP/CW
DISABLE
DISABLE
+
FAULT
+
FAULT
STEP/CW
DIR/CCW
DIR/CCW
+
+
+
RESET
RESET
+
STEP
OVER TEMP
MOTOR FAULT
POWER
SD17063
Stepper Drive
AC POWER
95 132 V
AC
50/60 Hz
INTERLOCK
B CTAP
B
B
EARTH GND
A CTAP
INTERLOCK
A
A
170Vdc present when the interlock
pins are connected. To reduce the
risk of shock, always install the
factory supplied rubber boot
over the connector.
GND
N
L
8.90"
(226.1)
8.02"
(203.7)
0.70"
(17.8)
max.
Total clearance of 3.0"
(76.2) needed for
Connector installation and removal.
5.53"
(140.5)
1.500"
(38.10)
0.400"
(10.16)
8.60"
(218.3)
0.152"
(3.86)
typ.
0.188"
(4.78)
1.280"
(32.51)
3.00" (76.2)
0.152" (3.86) dia.
0.312" (7.92) dia.
Grounding
Lug
0.81"
(20.6)
0.54"
(13.7) 1.250"
(31.75)
7.500"
(190.50)
#10-32 UNF-2B.
Four places.
Min. screw length = 0.31" (7.9) + thickness of mounting panel.
Max. screw length = 0.62" (15.8) + thickness of mounting panel.
0.200"