Specifications

Table Of Contents
CHOOSING YOUR SETTINGS
ADVANCED MICRO CONTROLS INC.
3
26
DIP Switch Settings (continued)
Motor Current (SB3-5 & SB4-1,2,3,4,5)
Figure 3.8 Motor Current Settings (4.3A – 6.3A)
Self Test
The Output Waveform feature is not needed when using full step resolution. When full stepping a motor, the
Pure Sine waveform is always used. Therefore, the SD17063 will enter its Self Test mode when the Step Res-
olution feature is set to Full Step, the Anti-Resonance feature is Disabled, and Output Waveform feature is set
to any value other than Pure Sine.
The drive will rotate the attached motor counter-clockwise at 60 RPM with 50,000 steps per turn. The
SD17063 will use the current waveform selected by the Output Waveform switches when driving the motor,
either -4%, -6%, or -10% 3
rd
harmonic. The SD17063 will continue to drive the motor until the switches are
changed and the drive is reset by the Reset Input or cycling power to the drive.
Self Test can be used to verify that the motor is wiring correctly to the drive. More information on the Self
Test mode can be found in Appendix C TROUBLESHOOTING, starting on page 53.
1
O
N
2345
SB1
1
O
N
2345
SB2
1
O
N
2345
SB3
1
O
N
2345
SB4
MOTOR CURRENT (Pg 3 of 3)
Switch Block 3: Switch 5 & Switch Block 4: Switches 1 – 5
4.8 Amps
5.6 Amps4.9 Amps
5.7 Amps5.0 Amps
5.8 Amps
4.3 Amps
5.1 Amps
5.9 Amps
4.4 Amps
5.2 Amps
6.0 Amps
4.5 Amps
5.3 Amps
6.1 Amps
4.6 Amps
5.4 Amps
6.2 Amps
4.7 Amps
5.5 Amps
6.3 Amps
= Not Used When Setting Motor Current