Specifications

CT1000
UNIVERSAL ACCESS CONTROL SYSTEMS
INSTALLATION AND WIRING INSTRUCTIONS
9
Form 77085 Rev. B 08-09-2005
ADVANCED PROGRAMMING FEATURES:
There are several advanced features which the CT1000 supports when manually configured:
DURESS ALARM: (Requires the use of a keypad) When a person is making an access attempt and wishes to set off
an alarm condition he/she can set off a “duress alarm” condition by pushing any keypad button within three seconds
of entering a valid access credential (including a code, card, or iButton.) Once this is done, the alarm relay will change
state and remain in such a state until a manual reset is given, either by a valid access credential, or by a REX input
(provided that the rex input is configured to clear an alarm condition - see dipswitch settings p. 3.) Note: when using
this feature it is important to train staff in the use of the feature to prevent false alarms and effectively provide the
added security.
DOORBELL FUNCTION: The doorbell function will change the state of the AUX relay for one second anytime the *
key is pressed. This can be used to sound a buzzer to alert someone inside that someone is at the door. (Best if used
with a sign which informs the guest that the * button is a doorbell.
LAMP FUNCTION: The lamp function will change the state of the AUX relay for 5 seconds anytime any of the keypad
buttons are pressed. The AUX relay is generally used in this case to light an otherwise dark entry whenever keypad
activity is detected. This feature could also, however, be used to alert security personnel of activity at a keypad.
REX INPUT CONFIGURATION: The request to exit input can be configured to activate the MAIN or the AUX relays or
both, depending on the requirements of the system. Note that the REX input can also be configured to clear or not to
clear an alarm condition (see dipswitch settings on p.3)
HOW TO CONFIGURE ADVANCED PROGRAMMING FEATURES:
A simple manual programming step is required to configure the above advanced features. Simply follow the steps out-
lined below:
1. ENTER A MASTER PROGRAMMING CODE/iBUTTON/CARD (wait for LEDs to stop flashing)
2. PRESS 7 9 9 * (wait for LEDs to stop flashing)
3. DURESS: ENTER 1 or 0 (1 = enable 0 = disable)
4. DOORBELL ENTER 1 or 0 (1 = enable 0 = disable)
5. LAMP ENTER 1 or 0 (1 = enable 0 = disable)
6. REX - MAIN ENTER 1 or 0 (1 = enable 0 = disable)
7. REX - AUX ENTER 1 or 0 (1 = enable 0 = disable)
7. ENTER *
END OF SEQUENCE
IMPORTANT NOTES!
1. If both DOORBELL and LAMP functions are enabled, the default will be that LAMP function is enabled.
2. If the REX - AUX function is enabled, the lamp and doorbell functions will not be enabled.
3. COMPUTER PROGRAMMED codes/cards/iButtons which are configured to activate the AUX relay will NOT disable
the doorbell or lamp function.