Specifications
CT1000
UNIVERSAL ACCESS CONTROL SYSTEMS
INSTALLATION AND WIRING INSTRUCTIONS
8
Form 77085 Rev. B 08-09-2005
System 7 Programming:
Follow this procedure to create 7 iButtons (or cards) without the use of a separate programmer. Note that 7 iButtons
or 7 cards can be entered and up to 7 more, provided that the first 7 were all cards or all iButtons. (If the first 7 were
cards then the second 7 must be iButtons and visa versa). The function will be determined by the order they are
entered, as shown below. Each time system 7 programming is done, previously “System 7” programmed
cards/iButtons will be erased. Computer programming, initializing a master iButton/card, or erasing memory will also
delete iButtons/cards programmed by this method.
1. Label the 7 iButtons/Cards as follows:
#1 User iButton/Card
#2 Toggle iButton/Card
#3 Lockout iButton/Card
#4 User iButton/Card
#5 User iButton/Card
#6 User iButton/Card
#7 User iButton/Card
2. Open cover of controller.
3. Momentarily depress the “CLR” and “INI” microswitch once at the same time. The red LED will turn on.
(Note: with 100CAB, TR80, or TR81, the LED(s) will not turn on.)
4. Touch iButton #1 to the reader (or swipe card). The LED will flash indicating acceptance.
5. Wait for the LED(s) to stop flashing before entering the next iButton (or swiping the next card). Repeat Step 4 using
iButton/card #2 through iButton/card #7.
6. If fewer than 7 iButtons (or cards) were programmed, press “INI” microswitch once to end programming. The LED
will turn off.
ERASING MEMORY (RETURN TO FACTORY DEFAULT SETTINGS):
Important: Resetting will delete all Keypad codes, iButtons/Cards, Master iButton/Card, and TEP programmers from
the lock memory. All time delays and default codes will be restored to default values.
1. Open cover of controller and set dipswitches according to chart on page 3.
2. Depress “CLR” microswitch three times. The red LED will turn on. (Note: with 100CAB, TR80, or TR81, the LED(s)
will not turn on.)
3. The operation is complete when the red LED turns off. (approx. 10 sec)
SETTING TIME DELAYS:
RELOCK TIME DELAY:
1. Enter master programming code/iButton/Card.
2. press “9 9 *” - wait for the LED(s) to stop flashing.
3. press “1 *” - wait for the LED(s) to stop flashing.
4. press the “1” button once for every second of relock delay desired.
5. press “*” to complete setting.
DOOR PROPPED TIME DELAY:
1. Enter master programming code/iButton/Card.
2. press “9 9 *” - wait for the LED(s) to stop flashing.
3. press “7 *” - wait for the LED(s) to stop flashing.
4. press the “1” button once for every second of relock delay desired.
5. press “*” to complete setting.
Note: If a long time delay is desired, you may press “5” instead of “1” (in step 4). This will enter time in 5 second
increments. Press “0” instead of “1”, for 10 second add. The CT1000 will add up the seconds. It doesn’t matter what