Specifications

CT1000
UNIVERSAL ACCESS CONTROL SYSTEMS
INSTALLATION AND WIRING INSTRUCTIONS
4
Form 77085 Rev. B 08-09-2005
2. MAKE WIRING CONNECTIONS: Note that the main relay is a double pole, double throw relay. TB4 will put
out DC unregulated voltage up to one Amp. Note that it is not necessary to use this terminal if your system already
uses DC voltage from a power supply. NOTE: Terminal blocks are removable (except TB4). See p. 11 for illustrations.
N.C.
COM
N.O.
N.C.
COM
N.O.
N.C.
COM
N.O.
N.C.
COM
N.O.
N.C.
COM
N.O.
MAIN R
ELAY
ALARM
RELAY
SW1-3
ON
ALARM
R
ELAY
SW
1-3 OFF
AUXILIARY
RELAY
RED LED
GREEN LED
1/2 KP BUT.
3/4 KP BUT.
* KP BUT.
GND
9/0 KP BUT.
7/8 KP BUT.
5/6 KP BUT.
VDD
I
NPUT POWER
12 OR
24VAC / DC
DC O
UTPUT POWER
AT TB3 INPUT VOLTAGE
(1 AMP MAX
.)
REQUEST TO EXIT INPUT
N.O. D
RY
CONTACTS
DOOR PROPPED OPEN, FORCED
DOOR & ANTI-TAILGATE INPUT
N.C. DRY CONTACTS
NOT USED
“CLR”
BUTTON
“INI”
BUTTON
FOR DIP SWITCH
SETTINGS SEE PAGE 3
Request to Exit: Closing contacts will activate relays for six seconds (timer adjustable see page 8)
Door Prop: Triggers Alarm Relay when door is held open for 30sec. (Requires door position switch.)
Anti-T
ailgate: Allows relocking of door immediately upon reclosing. (Requires door position switch.)
Forced Door:
Triggers Alarm Relay when door is forced open without a legal release. (Requires door
position switch.)
iButton DATA
GND
TR80/81 LED(+)
+VDD
DATA
CLOCK
PRESENCE
OPTIONAL INPUTS:
FOR WIRE COLORS
SEE NEXT PAGE.
DIAGNOSTIC
BUTTON
(SEE P.12)