Specifications

CT1000
UNIVERSAL ACCESS CONTROL SYSTEMS
INSTALLATION AND WIRING INSTRUCTIONS
3
Form 77085 Rev. B 08-09-2005
OVERVIEW OF INSTALLATION STEPS:
1. INSTALL COMPONENTS
A. Determine where each component will be located. Mount Controller and Power Supply to Wall. Run
conduit as required by local and national codes.
B. Follow instructions included with Access Control device to mount it and run wires to controller.
C. Mount Lock.
2. MAKE WIRING CONNECTIONS
A. Set Dipswitches correctly for your system.
B. Make wiring connections as required.
C. Use of the MOV spike suppressor (see page 12).
D. Connect Power
3. CONFIGURE AND PROGRAM SYSTEM
A. Initialize Master iButton/Card and programmer as required.
B. Configure and Program System.
C. Test System.
1. SET DIPSWITCHES FOR PROPER FUNCTION:
SW1-1 NOT USED
SW1-3 *ALARM RELAY: OFF=RELAY DE-ENERGIZED IN ALARM
ON = RELAY ENERGIZED IN ALARM
SW1-2 REX ALARM RESET: OFF= REX DOES NOT RESET ALARM
ON = REX DOES RESET ALARM
SW1-4 **ANTI-TAILGATE: OFF=DISABLE, ON=ENABLE
SW1-6 **DOOR FORCED/PROPPED: OFF=DISABLE, ON=ENABLE
SW1-8 NOT USED
SW1-7 AUTOMATIC RELOCK ON POWER-UP: OFF=RESET REQUIRED
ON=AUTOMATIC RELOCK
SW1-5 NOT USED
NOTES:
* Default SW1-3 OFF: Alarm relay is energized under normal condition. Therefore, when power is lost, an alarm
condition will occur. If SW1-3 is set to ON, then the controller will energized the relay in an alarm condition. With this
setting, loss of power will not be an alarm condition.
IMPORTANT! This setting will affect the “normal” condition of the relay terminals. (See wiring on next page.)
** These functions require a door status switch to be wired to the controller. The switch must be closed when the
door is closed. (See wiring on next page.)