Product guide

v4.5 - 12.18 .14 |
7
BACK TO T.O.C.
TeleBoss
TM
850-JITC Specifications & Pricing
BASE UNIT CONFIGURATION
2 RJ45 Serial I/O Ports
2 10/100 Ethernet Ports
2 or 6 Expansion Card Slots
AC Power Input
DEVICE SPECIFICATIONS
Unit Width: 11-17.5in / 27.94-44.45cm
Unit Height: 1.75in / 4.445cm
Unit Depth: 7.8in / 19.812cm
Unit Weight - dependent on
cong.: 3-5lbs / 1.36-2.27kg
Mounting: Shelf or 19in rack
Power: 15 VDC, 24 and 48VDC optional
ROHS / CE / CSA Certication: Yes
Power Consumption (Typical): 5.25W
Power Consumption (Max): 24W
BTUs (Nominal): 18 BTU/Hour
BTUs (Max): 82 BTU/Hour
Operating Temperature: 0-40° C
Storage Temp: -40° to +85° C
Operating Humidity: 10-80%
Storage Humidity: 0-95%
Mean Time Between Failure: 70,000 hr
OVERVIEW
The JITC versions of the T850-2 and T850-6 have been approved for use on the US Department of Defense network by
passing the JITC (Joint Interoperability Test Command) Certication process, and are a versatile and powerful system for
monitoring and control of remote telecom-centric equipment sites. The T850 facilitates data collection and telemanagement
of CPE and co-located telecom and other types of equipment located at remote sites. The T850 provides advanced features
for monitoring and control of serial devices, equipment I/O, and environmental conditions at these remote sites, with
notication when conditions fall outside limits. On-board I/O provides serial, and Ethernet connectivity. The T850-2 and
-6 models provide two or six expansion slots respectively to allow addition of various communications and monitoring I/O
interfaces that might be desired for your specic site application.
BACK PANEL CONFIGURATION
The T850 catalog number species the conguration and options you want to order with your T850 unit. The catalog number
lists the options in the order shown below. Items with a * are truly optional and are omitted if not desired.
BASE UNIT + *EXTENDED TEMP + MEMORY SIZE +
POWER SUPPLY + *EXPANSION CARDS
Base unit and base options are separated with a slash ( / ), then Expansion slot options are listed, separated with a dash ( - ).
The rst Expansion card listed in the catalog number goes in slot 1, the next in slot 2, and so on. Thus all of the following are
valid catalog numbers:
ADDITIONAL PRODUCT DETAILS
Unit comes with AC Desktop Power Supply with US-type IEC power cord, (2) 6ft RJ45 serial cables, (1) RJ45-DB9F DCE
Adapter, (1) RJ45-DB9M DTE Adapter, (1) DB9 M/F Null Modem Adapter, (2) 19” rack mount ears, and a documentation and
utilities CD. Expansion cards come with appropriate accessories. For example the 4X serial cards come with (4) 6ft RJ45
serial cables and (4) RJ45-DB9M DTE Adapters. Contact Sales for more details.
PRICING
TeleBoss 850-JITC with 2 Expansion Card
Slots (T850-2-JITC).................See Website
TeleBoss 850-JITC with 6 Expansion Card
Slots (T850-6-JITC).................See Website
Options:
Extended Temperature Range (/XT**)...$150
32MB Record Storage (/32M)........Included
64MB Record Storage (/64M)..............$450
AC Supply for US (/ACUS***)........Included
24VDC Power (/24DC****)....................$150
48VDC Power (/DC****).........................$150
Run-time Battery (/BB****)...................$200
JITC Maintenance Plan (WAR-06)..Contact Sales
T850-2-JITC BACK PANEL
OPTIONAL BATTERY
OR DC POWER
EXPANSION SLOT 1EXPANSION SLOT 2
RESET
I/0 2 I/0 1
ETH2 ETH1
SERIAL ETHERNET
DIP SW
SENSOR
PWR
T850-6-JITC/64M/ACUS-8V-8R-32C
T850-6-JITC/32M/ACEU-32C-4C4V
T850-6-JITC/32M/ACUS-8V-8R-32C
T850-2-JITC/32M/ACUS
T850-2-JITC/64M/ACUS
T850-2-JITC/64M/ACUS/BB
T850-2-JITC/32M/DC
T850-2-JITC/64M/ACUS-4S
T850-6-JITC BACK PANEL
OPTIONAL BATTERY OR
DC POWER
EXPANSION SLOT 1EXPANSION SLOT 2
RESET
I/0 2 I/0 1 ETH2 ETH1
SERIAL ETHERNET
PWR
EXPANSION SLOT 3EXPANSION SLOT 5
EXPANSION SLOT 4EXPANSION SLOT 6
DIP SW
SENSORMMC I/O
(disabled)
MMC I/O
(disabled)
** Standard operating temperature is 0
to +40°C. /XT option extends operating
temperature to -40 to +60°C. Extended-
temperature AC power supply included when
ordering /AC with /XT option.
*** For International usage you can specify /
ACUK, /ACEU, or /ACAU for UK, European, or
Australian power supplies respectively.
**** When determining your T850-JITC
conguration, you may choose either DC Power
or Run-time Battery, but not both.