Product guide
v4.5 - 12.18 .14 |
7
BACK TO T.O.C.
TeleBoss
TM
850-JITC Specifications & Pricing
BASE UNIT CONFIGURATION
• 2 RJ45 Serial I/O Ports
• 2 10/100 Ethernet Ports
• 2 or 6 Expansion Card Slots
• AC Power Input
DEVICE SPECIFICATIONS
• Unit Width: 11-17.5in / 27.94-44.45cm
• Unit Height: 1.75in / 4.445cm
• Unit Depth: 7.8in / 19.812cm
• Unit Weight - dependent on
cong.: 3-5lbs / 1.36-2.27kg
• Mounting: Shelf or 19in rack
• Power: 15 VDC, 24 and 48VDC optional
• ROHS / CE / CSA Certication: Yes
• Power Consumption (Typical): 5.25W
• Power Consumption (Max): 24W
• BTUs (Nominal): 18 BTU/Hour
• BTUs (Max): 82 BTU/Hour
• Operating Temperature: 0-40° C
• Storage Temp: -40° to +85° C
• Operating Humidity: 10-80%
• Storage Humidity: 0-95%
• Mean Time Between Failure: 70,000 hr
OVERVIEW
The JITC versions of the T850-2 and T850-6 have been approved for use on the US Department of Defense network by
passing the JITC (Joint Interoperability Test Command) Certication process, and are a versatile and powerful system for
monitoring and control of remote telecom-centric equipment sites. The T850 facilitates data collection and telemanagement
of CPE and co-located telecom and other types of equipment located at remote sites. The T850 provides advanced features
for monitoring and control of serial devices, equipment I/O, and environmental conditions at these remote sites, with
notication when conditions fall outside limits. On-board I/O provides serial, and Ethernet connectivity. The T850-2 and
-6 models provide two or six expansion slots respectively to allow addition of various communications and monitoring I/O
interfaces that might be desired for your specic site application.
BACK PANEL CONFIGURATION
The T850 catalog number species the conguration and options you want to order with your T850 unit. The catalog number
lists the options in the order shown below. Items with a * are truly optional and are omitted if not desired.
BASE UNIT + *EXTENDED TEMP + MEMORY SIZE +
POWER SUPPLY + *EXPANSION CARDS
Base unit and base options are separated with a slash ( / ), then Expansion slot options are listed, separated with a dash ( - ).
The rst Expansion card listed in the catalog number goes in slot 1, the next in slot 2, and so on. Thus all of the following are
valid catalog numbers:
ADDITIONAL PRODUCT DETAILS
Unit comes with AC Desktop Power Supply with US-type IEC power cord, (2) 6ft RJ45 serial cables, (1) RJ45-DB9F DCE
Adapter, (1) RJ45-DB9M DTE Adapter, (1) DB9 M/F Null Modem Adapter, (2) 19” rack mount ears, and a documentation and
utilities CD. Expansion cards come with appropriate accessories. For example the 4X serial cards come with (4) 6ft RJ45
serial cables and (4) RJ45-DB9M DTE Adapters. Contact Sales for more details.
PRICING
TeleBoss 850-JITC with 2 Expansion Card
Slots (T850-2-JITC).................See Website
TeleBoss 850-JITC with 6 Expansion Card
Slots (T850-6-JITC).................See Website
Options:
Extended Temperature Range (/XT**)...$150
32MB Record Storage (/32M)........Included
64MB Record Storage (/64M)..............$450
AC Supply for US (/ACUS***)........Included
24VDC Power (/24DC****)....................$150
48VDC Power (/DC****).........................$150
Run-time Battery (/BB****)...................$200
JITC Maintenance Plan (WAR-06)..Contact Sales
T850-2-JITC BACK PANEL
OPTIONAL BATTERY
OR DC POWER
EXPANSION SLOT 1EXPANSION SLOT 2
RESET
I/0 2 I/0 1
ETH2 ETH1
SERIAL ETHERNET
DIP SW
SENSOR
PWR
• T850-6-JITC/64M/ACUS-8V-8R-32C
• T850-6-JITC/32M/ACEU-32C-4C4V
• T850-6-JITC/32M/ACUS-8V-8R-32C
• T850-2-JITC/32M/ACUS
• T850-2-JITC/64M/ACUS
• T850-2-JITC/64M/ACUS/BB
• T850-2-JITC/32M/DC
• T850-2-JITC/64M/ACUS-4S
T850-6-JITC BACK PANEL
OPTIONAL BATTERY OR
DC POWER
EXPANSION SLOT 1EXPANSION SLOT 2
RESET
I/0 2 I/0 1 ETH2 ETH1
SERIAL ETHERNET
PWR
EXPANSION SLOT 3EXPANSION SLOT 5
EXPANSION SLOT 4EXPANSION SLOT 6
DIP SW
SENSORMMC I/O
(disabled)
MMC I/O
(disabled)
** Standard operating temperature is 0
to +40°C. /XT option extends operating
temperature to -40 to +60°C. Extended-
temperature AC power supply included when
ordering /AC with /XT option.
*** For International usage you can specify /
ACUK, /ACEU, or /ACAU for UK, European, or
Australian power supplies respectively.
**** When determining your T850-JITC
conguration, you may choose either DC Power
or Run-time Battery, but not both.