8 CONTACT CLOSURE SENSOR - 8C
Add 8 non-isolated contact closure inputs to any Asentria base unit.
• Works with relay-based units and TTL-based outputs
• Common ground across all contacts
8 CONTACT CLOSURE (ISOLATED) SENSOR - 8CI
Add 8 Isolated contact closure inputs to any Asentria base unit.
• Works with relay-based units and TTL-based outputs
• Each ground is electrically isolated for maximum electrical protection
4 VOLTAGE INPUTS & (4) ±15 VDC POWER OUTPUTS - 4VP*
Used in conjunction with up to four DC current transducers, this Expansion
Card can be used to measure DC current levels owing from battery banks or
power recti ers. Asentria can also provide the solid core or split core DC current
transducers from 50A to 500A con gurations. Power Monitoring EventSensors”
section for available ESV-TCDC current monitors.
• Voltage Range: -60/+60V
• Resolution: 0.1 VDC
*The 4VP expansion card cannot be used in conjunction with the internal “battery back-
up” option (/BB) on any SiteBoss unit that support the “BB” Internal Runtime Battery
4 VOLTAGE INPUTS & (4) 5 VDC POWER OUTPUTS - 4VP5
Add 4 Voltage Inputs and 4 5VDC power outputs, for use in powering sensors
which require a 5V power source and which output a variable voltage in return.
8 ANALOG VOLTAGE - 8V
Add 8 non-isolated analog voltage inputs to any Asentria base unit.
• Voltage Range: -60/+60V
• Resolution: 0.1 VDC
• Accuracy: +/- 0.5 VDC
• Common ground for all sensors
8 LOW-CURRENT RELAY - 8R
Add 8 relay outputs to any Asentria base unit
• Max switched voltage: 60V Peak (AC or DC)
• Max switched power: 30W (DC)
• Max switched current: 0.6A
8 4-20MA SENSOR - 8M
Add 8 non-isolated 4-20mA current inputs to any Asentria base unit.
• Resolution: 0.1mA
• Accuracy: 0.1mA
8 SOLID STATE RELAY SENSOR - 8SR
Add 8 solid state relay outputs to any Asentria base unit with an expansion slot
or as a variant to any ES-I/O product. Solid state relays provide a higher current
option than those on the 8R or ES-8R cards.
• Max switched voltage: 60V peak (AC or DC)
• Max switched power: 90W
• Max switched current: 1.5A
4 CONTACT & 4 SOLID STATE RELAY SENSOR - 4C4SR
Add 4 non-isolated dry contact closure inputs and 4 solid state relay outputs
to any Asentria base unit with an expansion slot or as a variant to any ES-I/O
product. Solid state relays provide a higher current option than those on the
4C4R card.
• Max switched VDC: 60 peak (AC or DC)
• Max switched power: 90W
• Max switched current: 1.5A
SPECIALTY
Asentria offers a variety of specialized Expansion cards for your application. From
communication to remote accessory connection, the growing list of Specialty
Expansion cards are designed to suit your particular need. Asentria base units
must have an Expansion slot to accept Asentria Expansion Cards. Refer to the
Product Matrix for more information on applicable units.
ADSL MODEM CARD - MA
Allows the Asentria unit to interface directly with an ADSL modem line. Card has
(1) RJ-11 connector.
• Includes (1) 7 ft. RJ11 Telephone Cable
4X RS232 SERIAL PORT CARD - 4S
Add 4 RS232 serial ports to a compatible Asentria base unit. Card has (4) RJ-45
type connectors.
• Baud rate: 300(Min) / 115200(Max)
• Includes (4) 6ft RJ-45 serial cables and (4) RJ45/DB9M DTE Adapters
2X RS485 2X RS232 SERIAL PORT CARD - 2DS2S
Add 2 RS485 and 2 RS232 serial ports to a compatible Asentria base unit.
Card has (2) RJ-45 type connectors and (2) Phoenix type connectors. Supports
connections to MODBUS devices.
• Baud rate: 300(Min) / 115200(Max)
• Includes (2) 6ft RJ-45 serial cables, (2) RJ45/DB9M DTE Adapters and
2 Screw terminal block plugs
4X 10/100 ETHERNET PORT CARD - 4E
Add (4) 10/100 Ethernet ports to a compatible Asentria base unit. Card has (4) RJ-
45 type connectors. Up to (2) 4E cards can be installed per unit.
• Allows independent IP address from unit’s other network interfaces
• Serves IP addresses via DHCP
• Simpli es site administration
• Integrates remote access
• Provides static routing and port forwarding
• Layer 2 switch
GPS RECEIVER CARD - GPS
Allows the user to pinpoint the exact location of any unit that supports it. This is
useful in applications where you wish to map the locations of many units.
4 CONTACT, (1) 5 VDC POWER OUTPUT,
1 VOLTAGE INPUT, 1 RESISTIVE SENSOR, &
(1) 4-20MA - 4C5P1V1F1M
Add 4 non-isolated dry contact closure inputs, (1) 5VDC power output (for use in
powering sensors which require a 5V power source and which output a variable
voltage in return), 1 non-isolated voltage input, 1 Resistive Sensor, and 1 non-
isolated 4-20mA current input to any Asentria base unit with an expansion slot.
2 CHANNEL HVAC VOLTAGE CONTROL CARD - VC1
Add (2) HVAC voltage control channels to a compatible Asentria base
unit.
• 1A per channel
INPUT/OUTPUT
Asentria’s Input/Output Sensor cards are the most common type of cards offered
and provide the greatest amount of exibility for your application. Featuring the
ability to operate in a passive or active environment depending on the card, the
I/O cards are the most popular. Asentria base units must have an Expansion slot
to accept Expansion cards. Refer to the Product Matrix for more information on
applicable units.
Expansion Cards