INSTALLING THE 820P PRO ETHERNET EXTENDER KIT
The Enable-IT 820P Pro IP PoE Camera Extender Kit has a distance restriction of 800ft
(244m) over existing Category 2, up to Category 5e, 6 or 7, wiring from device extension
to device extension. Therefore quick, simple site surveys and installation planning are
highly recommended.
This chapter describes the recommended installation process for the Enable-IT 820P Pro
Ethernet Extender Kit. The following topics are covered:
Site Plan – Installation Design Considerations
Unpacking the Enable-IT 820P Pro IP PoE Camera Extender Kit
Perform an Out Of The Box Test (OOTBT)
Performing the On-Site Installation
Site Plan – Installation Design Considerations
Total recommended distance of 1,100ft wiring from the 362 PoE Injector to the
LAN device on the remote end. – 328ft from LAN to 362, 328ft from 362 to 820P
Pro and 800ft from the 820P Pro to your end device is allowed.
Max distance then is 1,456ft (443m)
4 Pair Telco wiring for the Enable-IT 820P Pro Extended Ethernet Unit.
Wire pair used must be straight through, no taps/connection points.
Twisted Pair cabling delivers the best performance over distance.
Transparent to single line 802.3af PoE or 802.3at PoE Plus devices.
Option 1 – Single line PoE LAN Extension up to 800ft / 244m
We highly recommend a quick test to ensure the working order of your 820P Pro
kit.
Apply power to the 362 PoE Injector kit. Cable the power cord to the 362 power
brick adapter and use it’s DIN DC female connector to attach to the DC jack on the
back of the 362 Injector module.
Attach a RJ-45 LAN patch cord from your local LAN source to the Data N1 port
on the injector. Then run another LAN patch cord from the PoE&Data N2 port to the
LAN & PoE IN port on the 820P Pro unit.
Lastly, use a third LAN patch cord to attach your end PoE LAN device. The 820P
Pro unit and your PoE LAN device should now be powered up and running.