User manual
All Rights Reserved 1997 - 2013 Enable-IT, Inc.   Page 10 of 14 
DO NOT INSERT ANY BLANK RJ-45 HEADS INTO ANY 
PORTS BEFORE CRIMPING – OTHERWISE YOU WILL 
RENDER THE PORT USELESS – BENT PINS 
Attach RJ-45 Male heads to your existing wiring and follow 
the diagram below. For data only use pins 1,2,3 & 6. For 
Data and PoE use all pins. PoE uses pins 4,5,7 & 8 
Unpacking The Enable-IT 820P Pro IP PoE Camera Extender Kit 
Carefully remove the Enable-IT 820P Pro Kit’s packing materials from the box. Verify that 
the items listed below are present. Make sure that the equipment supplied matches what 
you ordered. If any items are missing or damaged, please contact Enable-IT or your 
distributor for assistance. 
  (1) Enable-IT 820P Pro IP PoE Camera Extender Unit 
(1) Enable-IT 362 PoE Injector kit 60W – 56V 
  (2) LAN Ethernet Patch Cords 
  (1) Enable-IT 820P Pro Quickstart Guide 
Performing The On-Site Installation 
After removing the Enable-IT 820P Pro IP PoE Camera Extender Kit from the box all that 
remains to install the unit on-site is to mount the unit, add RJ-45 Male heads to your wiring, 
connect the wiring, cross connect voice lines if needed and attach end device Ethernet 
patch cord cabling. 
 
Mounting the Enable-IT 820P Pro IP PoE Camera Extender Kit 
 The Enable-IT 820P Pro Extended Ethernet Units are designed for quick wall 
 mounting. Choose a location to mount each of the Enable-IT 820’s where the 
 maximum distance does not exceed 800ft (244m) total between devices to be 
 connected. 
When wall-mounting the units it is recommended that you use the appropriate screw 
anchors for your mounting surface. If mounting on existing plywood use wood screws; 
if mounting onto drywall or sheetrock, use plastic drywall anchors to secure your 
installation. 
 
Attaching cabling and devices to the Enable-IT 820P Pro IP PoE Camera Extender. 
 Apply power to the 362 PoE Injector kit. Cable the power cord to the 362 power brick 
   adapter and use it’s DIN DC female connector to attach to the DC jack on the back of  
 the 362 Injector module. 
 Attach a RJ-45 LAN patch cord from your local LAN source to the Data N1 port on the 
    injector. Then run another LAN patch cord from the PoE&Data N2 port to the LAN &  
 PoE IN port on the 820P Pro unit. 
 
Building the backbone between the 820P Pro unit and your remote LAN. 
  Crimp RJ-45 LAN heads onto your selected 4-pair wiring and insert into the 
 Interlink port on the 820P Pro unit and the other end to your LAN. 