Instruction Manual
EMX Industries, Inc. 7/10
OWL_Rev1.0_092220
Programmable Parameters
Setting Value
Button
Configure Relays – Set relay behavior (Presence/Motion)
NO/NO
NO/NC
NC/NO
NC/NC
Direction Detection – Prevents sensor from detecting objects moving away from it
Off
IR and
Microwave
IR
Microwave
Cross Traffic – Prevents sensor from detecting objects moving parallel to the door
Off
IR and
Microwave
IR
Microwave
Microwave Motion Sensitivity – Higher sensitivity increases area of detection
1 (Low)
2
3
4
5
6
7
8
9 (high)
IR Presence Sensitivity – Higher sensitivity lowers threshold of detection
1 (Low)
2
3
4
5
6 (High)
IR Rows – Adjusts which IR LED rows are on (see next page)
1 row
2 rows
3 rows
4 rows
All rows
IR Columns, Left Side – Adjusts which left-side IR columns are on (see next page)
None
2
4
All
IR Columns, Right Side – Adjusts which right-side IR columns are on (see next page)
None
2
4
All
IR Frequency – Change when multiple sensors are installed near each other to prevent interference
A
B
C
D
Presence Timer – Detection time before presence sensor relearns the local environment
30s
1min
2min
5min
10min
20min
1hr
2h
Never
Insect Mode – Reduce false detections from insects and other small objects
Off
On
Snow Mode – Reduces false detections due to snow. When set to Auto, will turn on below 40ºF (4ºC)
Off
Low
Med.
High
Low
Auto
Med.
Auto
High
Auto
Vibration Mode – Reduces false detections due to vibrations
Off
On
IR Detection Target – Configure IR to detect people and vehicles, or vehicles only
People
&
Vehicles
Vehicles
only
Default settings are bolded and colored in
Direction Detection and Cross Traffic functions will not work if any IR rows or columns are turned off
Left/Right columns are relative to the front of the sensor (see next page)