Instruction Manual

EMX Industries, Inc. 7/10
OWL_Rev1.0_092220
Programmable Parameters
Setting Value
Button
Configure Relays Set relay behavior (Presence/Motion)
NO/NO
NO/NC
NC/NO
NC/NC
Direction Detection Prevents sensor from detecting objects moving away from it
Off
IR and
Microwave
IR
Microwave
Cross Traffic Prevents sensor from detecting objects moving parallel to the door
Off
IR and
Microwave
IR
Microwave
Microwave Motion Sensitivity Higher sensitivity increases area of detection
1 (Low)
2
3
4
5
6
7
8
9 (high)
IR Presence Sensitivity Higher sensitivity lowers threshold of detection
1 (Low)
2
3
4
5
6 (High)
IR Rows Adjusts which IR LED rows are on (see next page)
1 row
2 rows
3 rows
4 rows
All rows
IR Columns, Left Side Adjusts which left-side IR columns are on (see next page)
None
2
4
All
IR Columns, Right Side Adjusts which right-side IR columns are on (see next page)
None
2
4
All
IR Frequency Change when multiple sensors are installed near each other to prevent interference
A
B
C
D
Presence Timer Detection time before presence sensor relearns the local environment
30s
1min
2min
5min
10min
20min
1hr
2h
Never
Insect Mode Reduce false detections from insects and other small objects
Off
On
Snow Mode Reduces false detections due to snow. When set to Auto, will turn on below 40ºF (4ºC)
Off
Low
Med.
High
Low
Auto
Med.
Auto
High
Auto
Vibration Mode Reduces false detections due to vibrations
Off
On
IR Detection Target Configure IR to detect people and vehicles, or vehicles only
People
&
Vehicles
Vehicles
only
Default settings are bolded and colored in
Direction Detection and Cross Traffic functions will not work if any IR rows or columns are turned off
Left/Right columns are relative to the front of the sensor (see next page)