Instruction Manual
EMX Industries, Inc. 4/10
OWL_Rev1.0_092220
4. Wire the OWL to the door operator per the wiring table below.
Wire Color
Description
Red
Power input + (12 to 24 VDC/VAC)
Black
Power input – (12 to 24 VDC/VAC)
White
Presence relay
Green
Presence relay
Yellow
Vehicle motion relay
Blue
Vehicle motion relay
Gray
Do not connect
Brown
Do not connect
5. Apply power and allow 10 seconds for unit to stabilize. The green LED will be flashing during this time.
Once stabilized (solid green LED), the sensor is operating, and the settings can now be configured.
LED Indicators
Green flashing
Sensor initialization
Green on
Standby
Red on
Presence output activated
Red flashing
Vehicle motion output activated
Yellow
Infrared sensor is detecting door
movement
Green/Red flashing
Internal sensor error
Instructions continue on next page