7. How to check if the Unit’s Relay is ON or OFF
You can check the current status of unit’s relay by SMS command as follows:
*Note: 9999 Is the password (default password 9999)
9999relay
The unit will reply by SMS according to the current status of the relay.
If the relay is OFF the SMS reply would be:
The relay is OFF
If the relay is ON the SMS reply would be:
The relay is ON
8. How to check the GSM Reception Level
Send SMS:
*Note: 9999 Is the password (default password 9999)
9999reception
The reception level of the GSM ranges from 0 to 5.
The unit will check the reception of the GSM network in the area and reply by SMS as follows:
The reception is 5
9. Automatic Learning of All Phone Numbers
The unit can be set to learn up to 1600 Normal Users automatically while the users call the unit
to activate the relay. In this mode the unit checks the caller’s ID (the mobile phone number) of
each incoming call and registers it automatically in the system’s memory and at the same time
triggers the relay according to the chosen setting.
To activate the Automatic Learning send SMS:
9999automatic
To cancel the Automatic Learning send SMS:
9999manual
The unit will reply by SMS accordingly:
Automatic Learning mode is ON
or
Automatic Learning mode is OFF