Phau Ntawv Qhia
EMX Industries, Inc. Tech support: 1216-518-9889 6/16
Document Number 10370104 Rev 1.1 technical@emxinc.com
The factory default setting for the relay is a MOMENTARY function (with a 1 second PULSE).
You can choose the required setting by SMS command as follows:
*Note: 9999 Is the password (default password 9999)
9999pulse01 For Momentary Function
9999latch For Latch Function
9999function For checking the current setting of the relay
The unit will reply accordingly to the above commands by SMS as follows:
Relay’s function is: Momentary Pulse of 1 second
Relay’s function is set for Latch function
If the unit is set for PULSE then:
The relay function is set to Pulse for 1 second
If the unit is set for LATCH then:
The relay is set to Latch Function
6. How to Set the Relay’s Pulse Time
The factory default time setting for the relay is a Pulse of 1 second.
You can choose and set the PULSE time interval of the relays by SMS as follows:
9999pulse - - -
The two hyphens “ - - ” after the word “pulse” represent the time in seconds up to 99 seconds.
Use the following commands to set the pulse time:
*9999 Is the password (default password 9999)
9999pulse00 for ½ a second pulse time.
9999pulse01 for 1 second pulse time (Factory Default)
9999pulse02 for 2 second pulse time
The unit will reply by SMS accordingly to the above as follows:
For example, send:
9999pulse00
The reply will be:
Relay’s function is Momentary Pulse of ½ a second.