User guide

3 Enterprise Virtual Array hardware components
This chapter describes the Enterprise Virtual Array hardware components.
Fibre Channel drive enclosures
The drive enclosure contains the disk drives used for data storage. A storage system includes
multiple drive enclosures. The major components of the enclosure are:
3U enclosure
Dual redundant, active-to-active 2 Gbps FC loops
2.125-Gb, dual loop, 14-drive enclosure
Dual 2 Gbps FC I/O modules (A and B loops)
Copper Fibre Channel cables
Fibre Channel disk drives and drive blanks
Dual redundant power supplies
Dual redundant blowers
Cache batteries
Environmental Monitoring Unit (EMU)
Enclosure layout
The disk drives mount in bays in the front of the enclosure. The bays are numbered sequentially
from left to right. A drive is referred to by its bay number. Enclosure status indicators are located
in the lower-right, front corner. Figure 6 (page 26) shows the front and rear views of the FC drive
enclosure.
Figure 6 FC drive enclosure—front and rear views
2. Drive bay 141. Drive bay 1
4. I/O module B3. EMU
6. Power supply 15. Blower 1
8. Power supply 27. Blower 2
10. Status indicators (EMU, enclosure power, enclosure
fault)
9. I/O module A
26 Enterprise Virtual Array hardware components