User guide
1.2.4.2 For VMware vSphere 5.1 or 5.0
1 Record the module name for the Converged Network Adapter card that is loaded into VMware ESXi.
The underlined portion indicates the loaded module name. In the following example, "lpfc820" is the
module name.
# esxcli system module list | grep lpfc
lpfc820 true true
Module names may vary depending on the Converged Network Adapter card that is used.
2 Check the number of ports on the Converged Network Adapter card.
The SCSI Host numbers of the Converged Network Adapter card that are displayed represent the number
of ports.
In the following example, the number of ports is "two" since "4" and "5" (two underlined portions) are
displayed as the SCSI Host numbers of the Converged Network Adapter card.
# ls /proc/scsi/lpfc820
4 5
3 Check the default value for the Converged Network Adapter card.
Specify the module name for the Converged Network Adapter card that you recorded in Step 1 and
check the default value.
# esxcli system module parameters list -m lpfc820 | grep lpfc[0-1]_lun_queue_depth
lpfc0_lun_queue_depth int Max number of FCP commands we can queue to a specific LUN
lpfc1_lun_queue_depth int Max number of FCP commands we can queue to a specific LUN
[0-1] indicates that the number of ports is two.
4 Change the setting values of the parameter for the Converged Network Adapter card driver.
Driver parameter Setting value
lpfcX_lun_queue_depth Arbitrary (*1)
(Up to 512 for each FCoE port of the ETERNUS DX)
*1: Recommended value = 512 ¸ (number of FCoE ports that are connected to a single CA port) ¸
number of LUNs
(Round the result down)
Use the value of "8" if the actual result is lower.
When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX Configuration
Guide -Server Connection- (FCoE) for VMware
®
ESX" and change the setting value for the Maximum
Outstanding Disk Requests for virtual machines as well.
Chapter 1 Setup Procedure for Emulex Converged Network Adapter Cards
1.2 Setting Up the Converged Network Adapter Cards
19
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
(FCoE) for VMware
®
ESX
Copyright 2014 FUJITSU LIMITED
P3AM-4772-10ENZ0