User`s guide
INSPEED MODEL 370 EMBEDDED STORAGE SWITCH
USER’S GUIDE CHAPTER 2: SWITCH INSTALLATION
EMULEX CORPORATION 9
P
ART NUMBER 00041367-003 REV. B
Ethernet LEDs
The Ethernet LEDs indicate the network connection status:
System LEDs
The System LEDs indicate the switch’s status, independent of the port LEDs.
Ethernet LEDs Indication
Ethernet Activity
(green LED)
• When flashing, the ethernet port is receiving data.
• When flashing rapidly, the traffic level is high.
Ethernet Link
(green LED)
When lit, the switch is connected to an operational ethernet.
System LEDs Indication
Fault
(yellow LED)
• When lit, one or more of the ports has failed or the internal temperature has
exceeded acceptable levels.
• When flashing, all ports are operational but another error has occurred. Errors
appear in an event log. The level of error severity that will cause flashing to
start can be controlled using the config sys fault command in the CLI. The
default is level 3, Critical.
Note: Whether lit or flashing, the switch will continue to operate. Switch
functionality may be impaired depending on the event that triggered the
Fault LED. Regardless of the cause, the switch requires immediate
attention.
Power
(green LED)
When lit, the switch is plugged in and the internal power supplies are functional.
2 Gb/s
(green LED)
When lit, the switch is set to operate at a speed of 2 Gb/s. When off, the switch is
set to 1 Gb/s.
Switch
Operational
(green LED)
• When lit, indicates that the switch has completed initialization for ports with
inserted SFPs and that the switch is operational.
• When flashing, the switch has been configured for multiple zones, and one or
more zones are up with at least one zone down.
If no zones (excluding hard zones) are operational, the LED turns off.
Figure 2-3: Ethernet LEDs
Ethernet Activity
Ethernet Link
Figure 2-4: System LEDs
Power
Switch Operational
Fault
2 Gb/s