Installation Guide

Page 63 of 67 pages
Document # E.0015.16.03 406984
PRESS OK TO
ACCEPT ZONE DATA
Press OK to accept the sensor type and serial number.
If the Control Panel receives no information from the sensor within a
predefined time, screen will show:
PU NOT FOUND
Disconnect sensor from battery or mains and reconnect, and try
again. If the same error message appears, replace the sensor.
When zone enrollment is complete, proceed to Place Test as
described below.
3.2.11 Place Test
From the Enroll Zones menu as shown in Section 3.2.10 above,
press DOWN key at top of Control Panel. Screen will show:
INSTALLER MENU
11: PLACE TEST
Note: This operation refers to the sensor for which Section 3.2.10
was just performed. Sections 3.2.10 and 3.2.11 must be performed
for all sensors the first time the IntegrAlarm system is installed, and
(under normal circumstances) need not be performed thereafter.
Press OK at top of Control Panel. Screen will show:
PLEASE ACTIVATE
THE ZONE
Go to zone 1, install the sensor and connect its battery (or connect it
to mains, as applicable). The sensor will transmit its serial number,
type and mode to the Control Panel.
If the Control Panel receives this information from the sensor within
a predefined time, screen will show:
S/N: XXXX
TYPE: YYYY