Installation Guide
Page 62 of 67 pages
Document # E.0015.16.03 406984
On conclusion of all sub-functions (when sub-function 01 is again
displayed), press ESC to return to Download Options menu. Now
press DOWN key at top of Control Panel to proceed to the Enroll
Zones menu.
3.2.10 Enroll Zones
From the Download Options menu as shown in Section 3.2.9 above,
press DOWN key at top of Control Panel. Screen will show:
INSTALLER MENU
10: ENROLL ZONES
Note: Sections 3.2.10 and 3.2.11 must be performed for all sensors
the first time the IntegrAlarm system is installed, and (under normal
circumstances) need not be performed thereafter.
Press OK at top of Control Panel. Screen will show:
ENTER ZONE # 1
FRONT DOOR
To confirm Zone 1 as the zone now being enrolled, press OK at top
of Control Panel. To change the default, key in the desired number
on numeric keypad and press OK at top of Control Panel.
Screen will show:
PLEASE POWER UP
THE ZONE
Bring the sensor for zone 1 close to the Control Panel and connect
its battery (or connect it to mains, as applicable). The sensor will
transmit its serial number, type and mode to the Control Panel.
If the Control Panel receives this information from the sensor within
a predefined time, screen will show:
S/N: XXXX
TYPE: YYYY
Screen will then change to: