Installation Guide
Page 59 of 67 pages
Document # E.0015.16.03 406984
05: EXIT ERR. 00
RECENT CLOSE 00↵
To confirm the hexadecimal codes which will indicate in the report
that an exit error has been made in the installation process (an
entry/exit zone is violated when the system is armed, and the
system is immediately disarmed thereafter) and that a recent close
event has occurred (an alarm occurs within two minutes after arming
the system), press DOWN at top of Control Panel. To change the
default, key in the desired codes on numeric keypad and press OK
and then DOWN at top of Control Panel.
On conclusion of all sub-functions (when sub-function 01 is again
displayed), press ESC to return to Report Codes menu. Now press
DOWN key at top of Control Panel to proceed to the Download
Options menu.
3.2.9 Download Options
From the Communications Options menu as shown in Section 3.2.8
above, press DOWN key at top of Control Panel. Screen will show:
COMMUNICATIONS
4. Download Opt.
Press OK at top of Control Panel. Screen will show:
01: DOWNLOAD
Enable ↵
To enable downloading and proceed to the next download option,
press DOWN key at top of Control Panel. To change the default from
Enable to Disable, press OK at top of Control Panel (if Disable is
displayed, press OK at top of panel to change to Enable) and then
press DOWN key at top of Control Panel to proceed to next sub-
function. Screen will show:
02: DOWNLOAD TEL
23 ↵
If 23 is the correct telephone number for the download option, press
DOWN key at top of Control Panel to proceed to next sub-function.