Installation Guide

Page 54 of 67 pages
Document # E.0015.16.03 406984
To confirm the hexadecimal codes which will indicate in the report
that tampering has occurred in this zone and that the system has
subsequently been restored to normal operation, press DOWN at
top of Control Panel. To change the default, key in the desired codes
on numeric keypad and press OK and then DOWN at top of Control
Panel to proceed to next sub-function. Screen will show:
04: L. BATT. EV. C0
Restore D0
To confirm the hexadecimal codes which will indicate in the report
that a low battery event has occurred in this zone and that the
system has subsequently been restored to normal operation, press
DOWN at top of Control Panel. To change the default, key in the
desired codes on numeric keypad and press OK and then DOWN at
top of Control Panel to proceed to next sub-function. Screen will
show:
05: BYPASS EV. E0
Restore F0
To confirm the hexadecimal codes which will indicate in the report
that this zone has been bypassed and that the system has
subsequently been restored to normal operation, press DOWN at
top of Control Panel. To change the default, key in the desired codes
on numeric keypad and press OK and then DOWN at top of Control
Panel.
On conclusion of all sub-functions (when sub-function 01 is again
displayed), press ESC to return to Zone Codes menu. Now press
DOWN at top of Control Panel to proceed to the next sub-function,
Emergency Alarm
.
Screen will show:
REPORTING CODES
6. Emerg. Alarm
Press OK at top of Control Panel. Screen will show:
01: PANIC EV. B1
Restore B2