Installation Guide

Page 53 of 67 pages
Document # E.0015.16.03 406984
This defines the communications options provided by the system. To
view the first Central Station options, press OK at top of Control
Panel. Screen will show:
REPORTING CODES
1. Zone Codes
Press OK at top of Control Panel. Screen will show:
ENTER ZONE # 1
FRONT DOOR
To confirm Zone 1 as the zone now being programmed, press OK at
top of Control Panel. To change the default, key in the desired
number on numeric keypad and press OK at top of Control Panel.
Screen will show:
01: ALARM EV. 60
Restore 70
To confirm the hexadecimal codes which will indicate in the report
that an alarm event has occurred in this zone and that the system
has subsequently been restored to normal operation, press DOWN
at top of Control Panel. To change the default, key in the desired
codes on numeric keypad and press OK and then DOWN at top of
Control Panel to proceed to next sub-function. Screen will show:
02: TROUBLE EV. 80
Restore 90
To confirm the hexadecimal codes which will indicate in the report
that a malfunction event has occurred in this zone and that the
system has subsequently been restored to normal operation, press
DOWN at top of Control Panel. To change the default, key in the
desired codes on numeric keypad and press OK and then DOWN at
top of Control Panel to proceed to next sub-function. Screen will
show:
03: TAMPER EV. A0
Restore B0