Document # E.0015.16.03 406984
02: SIREN TIMEOUT (default 6 minutes)
03: FIRE SIREN TO (default 8 minutes)
After completing each of the above sub-functions, press ESC at top
of Control Panel to return to Sounder Timers menu. Now press
DOWN key at top of Control Panel to proceed to next sub-function:
Communication Timers
.
Screen will show:
TIMERS & COUNTER
3. Comm. Timers
Press OK at top of Control Panel. Screen will show:
01: ABORT TIME
30 seconds ↵
If 30 seconds is the correct setting for abort time, press DOWN key
at top of Control Panel to proceed to next sub-function.
To change the abort time
, press OK at top of Control Panel. The "6"
in 30 will blink. Using the numeric keypad like a cellular telephone
keypad, change the "6" to the desired digit. The "0" will then blink.
Change the "0" to the desired digit. Now repeat the process for each
of the following sub-functions:
02: INST. DLG. T/O (default 20 minutes)
03: USER DLG. T/O (default 3 minutes)
04: CODE DLG. T/O (default 45 seconds)
05: TX DEL: AC TRB (default: 60 minutes)
06: BACKLIGHT T/O (default: 10 seconds
07: SENSOR SUPRVS (default: 60 minutes)
08: PGM/X-10 TIME (default: 30 second)
After completing each of the above sub-functions, press ESC at top
of Control Panel to return to Communication Timers menu. Now
press DOWN key at top of Control Panel to proceed to next sub-
function: Keypad Lockout
.
Screen will show:
TIMERS & COUNTER
4. Keypad Lockout