Installation Guide

Page 21 of 67 pages
Document # E.0015.16.03 406984
10: SIREN DELAY
01
If 1 second is the correct report delay setting for this zone, press
DOWN key at top of Control Panel to proceed to next sub-function.
To change the siren delay time
, press OK at top of Control Panel.
The "0" in 01 will blink. Using the numeric keypad like a cellular
telephone keypad, change the "0" to the desired digit. The "1" will
then blink. Change the "1" to the desired digit. Now press DOWN
key at top of Control Panel to proceed to next sub-function.
Screen will show:
11: X-10 1 2 3 4
N N N N
To select the types of messages to be sent with regard to this zone
(Note: a list of zone types appears in the Appendix to this manual),
press "0" key on numeric keypad of Control Panel for NO or "1" for
YES for each of the following sub-functions:
11: X-10 1 2 3 4 (X-10 equipment operated from this zone)
12: X-10 5 6 7 8 (additional X-10 equipment operated from this
zone)
13: PGM 1 2 (PGM equipment operated from this zone)
After completing each of the above sub-functions, press DOWN at
top of Control Panel to proceed to next sub-function.
After sub-function 13 is complete, screen will show:
14: REMOTE USER
MASTER
If Master is the correct setting for this zone, or if this is not a zone
which has a remote user, press ESC key at top of Control Panel to
return to Zone Programming menu and press DOWN key to proceed
to next sub-function.
To change the remote user type, press OK at top of Control Panel.
The character will be replaced by ‡. Screen will show: