2. The EMV3000 is mounted with 3 screws (reference D02) and 3 spring lock washers (reference
D03) on the mounting frame (Figure 5).
Torque setting screwdriver: 40 N.cm
Figure 4: Mount EMV3000
6.2 EMV3000 Cable connection(s)
Always integrate a cable strain relief when connecting the EMV3000. This to avoid bad connections
and loss of data and power connection over a period of time.
6.2.1 Connection via micro-USB cable
The EMV3000 is connected via a micro-USB cable (Figure 6).
Emsyscon advises to use a cable length of maximum 2 meters.
Figure 5: Connection via micro-USB cable
Mounting frame
(example)
D02
D03
D01
T02
T01