Red indicator. User can try recycling the power which will allow the unit to go thru its
automatic set up operation but if the problem persists contact your service provider.
Indicators
The Link2Cellâ„¢-19 is equipped with three LED indicators on the end of the unit which
provide the following information:
During normal operation:
Indicator State Description
Green Off No DC Input Power Applied
Solid Indication DC Power on, normal function
Flashing Indication System Initialization, Auto Set Up
Red Flashing Indication Warning, fault condition
(Unit will reset gain to stable
operation)
Solid Indication Alarm
(Contact your Service Provider)
Amber Flashing Indication No RF Signal Detected
(<-90 dBm)
Solid Indication Weak RF Signal
(>-85 dBm)
Initial System Automatic Set Up:
(First 2-3 minutes of DC power being applied)
Indicator State Description
Green Flashing Indicator System Initialization, Auto Set Up
Amber/Red Solid On, Both >76 dB Gain
Amber Solid On Indication >73 dB Gain
Red Solid On Indication >70 dB Gain
Amber/Red Flashing Both >67 dB Gain
Amber/Red Off, both <64 dB Gain
*Green Indicator will go to a solid indication once the initial set up is complete.