SNMP Reporting Format
Overview of SNMP Reporting
Heartbeat – Periodic Reporting
This table is intended to describe the periodic reporting requirement. The transport mechanism
is UDP using SNMP version 3 (USM compatible) protocol. Alarms are sent via INFORM PDU.
Heartbeats are sent via TRAP PDU. Self-reporting will use the following format: Site ID, Date,
Time, Parameter Name, Alarm Status.
Note: all existing sites will need to be updated to the existing format if a reporting
capability is desired.
Item
Number
Name Description
8.
Site ID
Site ID is the repeater Network identification
9.
Date
Date be in the form: MM/DD/YEAR (i.e., 09/26/2003)
10.
Time
Time be in the form: HR:MIN:SEC (i.e., 19:54:36)
11.
Parameter
Number
1 = HEART BEAT
12.
Alarm Status
Alarm Status = SET
An example of the wireless periodic reporting (heartbeat) follows:
Repeater Number1|09/26/2003|19:54:36|HEART BEAT|SET
This Identifies a Repeater Number 1, which is outputting a “heartbeat” message on September
26, 2003 at 7:54:36 PM.
Self-Reporting Alarms
This table is intended to describe how the network repeater generates a self-alarming report:
Site ID, Date, Time, Alarm Parameter, Alarm Status. Each alarm occurrence generates a
complete message with the requirement as described in this table.
Item
Number
Name Description
13.
Site ID
Site ID is the repeater Network identification
14.
Date
Date be in the form: MM/DD/YEAR (i.e.,
09/26/2003)
15.
Time
Time be in the form: HR:MIN:SEC (i.e., 19:54:36)
16.
Alarm Parameter
Alarm Parameter will be one of the following:
1. 2 - RF Pilot Power
2. 3 - VSWR
3. 4 - RSSI
4. 5 - Over/Under Current
5. 6 - Over Temperature