User's Manual

Preliminary Document
CI Wireless Inc. 11/19/99 5
signal paths. Removing DC power from the unit for a period of 30 seconds or longer will
reset the auto shut down.
Failure Action Alarm Code
Alarm Cleared 0
Synthesizer Lock, Uplink Auto Shut Down 1
Synthesizer Lock, Downlink Auto Shut Down 2
Downlink RF Overdrive Auto Shut Down 3
Uplink RF Overdrive Auto Shut Down 4
No Downlink RF Detected* Alarm Only 5
Internal Voltage Failure Alarm Only 6
Low Current Draw Alarm Only 7
Keep Alive
(1)
Auto Shut Down 8
*Minimum detectable RF level is approximately –10dBm. Unit will alarm below this level.
(1)
Not applicable unless equipped with remote alarms. On units with remote alarms it must be
activated when the remote messaging is set up.
Keep Alive
The Mini Keep Alive feature can only be activated once the modem has been installed. Once
activated by the user in the program mode, this feature requires the Mini, or a remote
computer, to have contact at least once daily. If no contact is completed, the Mini will shut
down and activate an alarm.
The Mini can be programmed requiring a Keep Alive activation from as often as the user
desires, but at least once daily. The factory default requires one daily activation and is set to
occur between 3:00 and 4:00 AM.
Indicators
The Mini is equipped with three LED indicators on the end of the unit which provide the
following information:
Indicator State Description
On/Alarm Off No DC Input Power Applied
Green DC Power on, normal function
Green Flashing DC Power on, Set up fault-Band
Selection
Red Flashing Fault Conditon 5 Minute Warning
(See list of alarms)
Red Alarm