User's Manual

Preliminary Document
CI Wireless Inc. 11/19/99 4
Pin 10 digits
Alarm Code 20 numeric digits
2. Telephone Number 20 digits, maximum
Include required access codes such as 9 if required by a
PBX. A comma is used to insert a delay.
Pin 10 digits
Alarm Code 20 numeric digits
Delay 3 numeric digits, 0 to 999 minutes
3. Telephone Number 20 digits, maximum
Include required access codes such as 9 if required by a
PBX. A comma is used to insert a delay.
Pin 10 digits
Alarm Code 20 numeric digits
Delay 3 numeric digits, 0 to 999 minutes
A factory default password is preprogrammed into the unit as 10000. The user may change
this in the program mode of operation. There is also a factory access password.
Up to three numbers and alarm codes or paging pin numbers can be sent. The unit will send
an alarm to the first number when an alarm occurs. (The alarm is not sent during the red
flashing alert period. It is delayed 5 minutes to be certain the alarm will not clear itself).
Each additional number and alarm, which has a programmed sequence, will be sent after the
programmed delay. The delay, which is set, is a time measurement from initially sending the
first telephone call and alarm.
Should an alarm condition clear, the Mini will send an Alarm Clear alert to the same number
or numbers that were alerted previously. As an example the alarm condition could occur if
the base station was turned off for maintenance.
The unit will record time, date and cause of the last 25 reportable (alarms present after 5
minute alert delay) alarms. The user may download these via the modem connection or
factory personnel may also review them. Retrieving log history requires entering the
password.
Command, Clear Log File, is accessible only with the factory password.
Alarms
All alarms are considered major since there is no field replaceable modules in the unit. All
alarms are indicated locally immediately by the Alarm LED indicator blinking red. Once the
Alarm State has existed for 5 minutes, the Alarm LED will have a constant red indication.
Certain problems will result in the unit automatically shutting down after 5 minutes of sensed
failure. This is done by disabling the RF output stages in both the up link and down link