Parameters
MINI-19 Forward Reverse
Operating Frequency, (MHz) 1930 to 1990 1850 to 1910
Band Selective A, B, or C, (MHz), 1 dB Bw 14.75 14.75
Band Selective, D, E, or F, (MHz), 1 dB Bw 4.75 4.75
Gain, (dB), Adjustable in 2 dB steps 40 to 70 40 to 70
Peak Limiting adjustable, (dB) 14 14
Gain Flatness, (dB) +1/-2 +1/-2
Noise Figure, (dB) ≤8 ≤8
Return Loss (dB) 15 15
Composite Power, User Selectable, (dBm) 6 to 20 6 to 20
(Up Link tracks down link setting)
Group Delay, (usec) ≤4 ≤4
Spurious Emissions,
Out of Band, (dBm) ≤13 ≤13
Input RF Signal, (dBm) <-20 <-20
Operating Temperature, (°C) +5 to +45 +5 to +45
Primary Power, (VAC) 90 to 260
Current Draw, (Amps) .5
Enclosure Dimensions, HxWxD, (Inches) 2.25x7x14.5
Weight, (lbs.) 6.5
MTBF, (hours) 75,000
RF Connectors, Donor, Rerad (2) N/Female
Alarms,
Power On
Forward Signal,
No RF Detected/ RF Detected / Overdrive
Current
Reverse Signal,
RF Detect / Overdrive
Optional Remote Alarms Telephone Modem