User's Manual

Preliminary Document
CI Wireless Inc. 11/19/99 10
Trouble Shooting:
The Eko-Mini has no field replaceable parts; repair is down to improper set up or software
programming, installation or defective units.
Problem Check Corrective Action
No Power Power Source Reconnect or repair
Power Source OK Replace Unit
Alarm Indication No RF Downlink Indication Check RF Input Source
No Uplink RF Indication Check RF Antenna Input
Recycle AC Power No Change
Reset Switch No Change
Replace Unit
Remote Alarms inoperable Generate Alarm, remove RF
input
Program Software
Software OK, Check Telephone line
Telephone Line OK Replace Unit
No RF DownLink Power Check Band Switches Set Switches & recycle
Power
Switches Set properly Replace unit
Low DownLink RF Power Check Input Power Level Relocate Donor Antenna,
improve signal strength
Increase Donor Antenna
Gain
Shorten Coaxial Cable length
Signal Strength Good Reset Switch, Start new
system set up
Low RF Output Power Replace Unit