User's Manual
EMS Wireless
EMS Wireless EkoMini Manual
16
Introduction
EkoMini is quick and easy to install, using a minimum set of common tools. This
section will provide the basic steps to performing the installation of EkoMini. Please
read complete instructions before beginning assembly.
Getting Started:
Unpack all of the boxes and insure all of the material is included for your installation
requirements and undamaged in shipment.
QTY Description
1 EkoMini
1 +9 VDC Power Module
1 AC Power Cord
1 Manual
1 Test Data, Factory
1 *Optional, Telephone cable 6 ft.
*Only needed with external alarm.
Mounting:
EkoMini is designed for optimum use as an in-door repeater. The housing is not
weather resistant and the automatic set up procedure assumes sufficient
isolation between antennas is assured. When the donor antenna is mounted
outside and the rerad/server antenna is mounted inside of a building isolation is
assured to be adequate.
Since the EkoMini has a minimum gain of 40 dB, isolation of at least 55 dB must
be obtained between the donor and the rerad antenna. Should adequate isolation
not be obtained an oscillation could occur which could cause damage to the unit.
-Connect coaxial cables to the Donor and Rerad ports.
-Connect primary power module to AC source and connect 9 VDC output to EkoMini
DC Input.
-Optional connect telephone line to RJ11 jack.
Refer to attached drawing for any clarification. (Page 16)
Select Mounting location of Donor directional antenna and orient toward the base
station to maximize signal level. For best performance this should be line of sight
between the Donor antenna and the base station antenna.