User's Manual

EMS Wireless
EMS Wireless EkoMini Manual
14
The EkoMini can be programmed requiring a Keep Alive activation from as often as the
user desires, but at least once daily. The factory default requires one daily activation
and is set to occur between 3:00 and 4:00 AM.
Indicators
The EkoMini is equipped with three LED indicators on the end of the unit which provide
the following information:
Indicator State Description
On Off No DC Input Power Applied
Green DC Power on, normal function
Green Flashing DC Power on, Set up fault-Band Selection
Alarm Off No Alarm
Red Flashing 5 Minute Warning
(See list of alarms)
Red Alarm
Uplink RF Power levels per picture below
Downlink RF Power levels per picture below
No RF Uplink Detected; this is a normal state for the uplink RF path. The normal levels
of RF received and amplified from the subscriber unit may be below the –10 dBm
+9 VDC
TELE
ALARM
UPLINK
DOWNLINK
ON
OD
20
15
10
5
0
-5 -10
OD
20 15
10
5
0-5-10
UPLINK
POWER LEVEL
DOWNLINK
POWER LEVEL