2.
Remove 4 screws inside securing unit to panel
3.
Reinstall replacement module.
Caution:
please secure with mounting
screw when reinstalling module on panel
4.
Reinstall panel reversing procedure
Replacement of Control Module or 700-1004 Board Assembly
• Turn Off and Disconnect Power
from the Remote Unit
•
Assemblies can be replaced without removing panel.
•
Replacing the Controller
1.
Disconnect 26 conductor ribbon cables from J1 & J2 on 700-1004 board
assembly
2.
Remove 4 mounting screws and lift controller from panel
3.
Reinstall by reversing procedure.
Caution:
Be sure ribbon cables are
properly dressed to prevent damage when closing & opening door.
•
Replacing 700-1004 Assembly
1.
Disconnect cables from J1, J2, J3 and J4
2.
Disconnect cables from terminal strips, RS-485, Door Intrusion switch and
10 Pin terminal
3.
Remove 4 mounting screws and lift module from panel
4.
Insure replacement board has proper Jumper placement and install
reversing procedure
5.
Check PA Output for proper calibration adjustments are made using VR1
on board assembly