User's Manual
CI Wireless Inc.
1211 Ira E. Woods Ave., Grapevine, TX 76051
46
8.3 RS 232 Port Communications
.
A. Hyper Terminal Connection
To use the hyper terminal capabilities of the EkoCel™, you must have the enclosed adapter
attached to the controller. If no adapter was included please contact the factory for replacement.
This part # is 900-1000-072, consisting of the D-Sub/9 Pin Adapter, 6’ of cable and a RJ-12
connector.
Settings for your terminal emulator should be:
Direct connect to comport
9600 bps
8 bits
1 Stop bit
No parity
No flow control
Once the setup of the emulator is ensured and connection is made, go to the menu “RS 232 Port
Mode” and select Terminal from the list of choices, if a modem is being used, select MODEM.
To access the controls and menus of the EkoCel™, a VALID password MUST be entered. The
passwords are the same as the unit passwords supplied earlier in this manual. The following is a
list of all commands within the menus.
Note: All commands can be typed in all Lowercase or Uppercase But not a mixture(ie..Set Ul 23).
Terminal Interface Displays:
Maintenance Screen
Command to show:
MAIN
Shows below:
1.9GHz 800MHz
R1 R2 R3 R4 R5 R6 R7 R8
Hub
Tx Base Station Input (dBm) 28.4 n/a n/a n/a n/a n/a n/a n/a
Tx Laser Power (dBm) -1.6 n/a n/a n/a n/a n/a n/a n/a
Remote
UPLINK
Attenuation (dB) 23 n/a n/a n/a n/a n/a n/a n/a
RSSI (mV) 1082 n/a n/a n/a n/a n/a n/a n/a
RF Loss (dB) 2 n/a n/a n/a n/a n/a n/a n/a
Optical Loss (dB) 1 n/a n/a n/a n/a n/a n/a n/a
DOWNLINK
Dac (mV) 3122 n/a n/a n/a n/a n/a n/a n/a
PA Detect (mV) 2544 n/a n/a n/a n/a n/a n/a n/a
Peak Power (dBm) 34 n/a n/a n/a n/a n/a n/a n/a
RF Loss (dB) 2 n/a n/a n/a n/a n/a n/a n/a
Optical Loss (dB) 1 n/a n/a n/a n/a n/a n/a n/a
TEMPERATURE (˚C) 24.6 n/a n/a n/a n/a n/a n/a n/a