User's Manual
EMS Wireless Operator’s Manual
MirrorCell II CDM 812, CDM1912 Series
608112-1, Rev C
26
all the software commands available in the repeater.
Type ‘STATUS’ and press ‘enter’ to verify the current repeater settings. Also, the
‘STATUS’ command can be used after every software parameter is changed to
verify the current setup. The screen should appear similar to Figure 8 below.
Figure 8: Status Screen
The UL and DL passband center frequencies are normally preset at the factory.
However, they can be changed by the user, if, for example, the user requires
greater attenuation of adjacent out of band frequencies.
To set the peak limit for the unit type ‘SET PEAK #’, where ‘#’ is any number
between 18 and the repeater’s maximum rated output power in dBm plus 1.
(Example: To limit the peak power to +27 dBm, type ‘SET PEAK 28’.) The
default factory setting is the repeater’s maximum rated output power plus 1. If
maximum power is desired, then skip this step.
System
Date/Time
Repeater Serial
and Model
Automatic Time
Log
DL and UL
Passband
UL RF Gain Offset
Relative to DL Gain
Peak DL Power Level
with all channels driven
Alarm
Condition
DL and UL
Attenuation Settings
Repeater Internal