User's Manual
CI Wireless Inc. 1211 Ira E Woods Ave 45
Tel: 817 416 0583 Grapevine, TX 76051
D. Maintenance Menu
This set of menus contain many readings that will be useful during the calibration and or
trouble shooting after problems occur. Some of these readings update in real time, but
most are network related an update every 20-30 seconds. . If changes occur to the
readings the user will NOT see them unless the Item key is used to scroll around back to
it, then the value will be updated. If the second is true and the remote is not installed,
ANY information displayed will be invalid. The readings and their definitions are as
follows:
Tx Pwr Lzr mV: XXXX The voltage returned from the detector to the
controller to u3. Helps to determine the TX pwr.
UL # RF Loss: XXXX The average amount of RF loss on the uplink path
UL # Optc Los: XXXX The average amount of Optical Loss uplink path
UL # Atten Set: XXXX Amount of direct Attenuation to the uplink path
UL # Rssi mV: XXXX Voltage returned from Uplink Signal Strength
** DL # Rssi mV XXXX Voltage returned from Downlink Signal Strength
** DL # RF Loss: XXXX The average amount of RF loss on the downlink path
** DL # Optc Los: XXXX The average amount of Optical Loss downlink path
DL # Gain mV: XXXX Voltage being put out by controller to the PA.
DL # Pwr SET: XXXX User Defined in Gain Cntrls. Amount of PA output
power at #
E. Date & Time
Only the supervisor’s password has access to this feature. To flip between setting the
time or date, press the ITEM key. The FIELD key changes the digit to be edited and
again the arrow keys change the digit. Press the MENU key when finished.
F. Event History
The events history log will store the last 50 events to take place on both the microcell and
hub side of the network. By selecting “yes” at the menu prompt, scrolling through the
event history will be possible by pressing the ‘ITEM’ key. Events will be displayed with
the date at the top, the remote number and the alarm or event originated on the second
line. Remember that the remote number for the hub is “0”. If at any time you wish to
exit the menu simply press the Menu key then select no and press the Menu key again.