User's Manual
CI Wireless Inc. 1211 Ira E Woods Ave 44
Tel: 817 416 0583 Grapevine, TX 76051
8.2.3. USER SETTINGS on HUB CONTROLLER
A. Accessing User Menus
Hub - to access the user menus first the ADD key must be pressed. Due to background
functions operating sometimes you may have to hold the ADD key for nearly a second.
The result will be the Password Entry Screen. In order to proceed to other menus a valid
password must be entered. The controllers are delivered with a set of factory passwords.
The factory passwords can be altered by using the supervisor password only. Once the
desired password is entered press the MENU key to proceed or the DEL key to return to
normal functioning. Units are set with an initial default passwords: Supervisor - 21314,
Tech 1 - 11311, Tech 2 - 11312, Tech 3 - 11313, Tech 4 - 1000.
B. Readings / Controls
Hub - gain is adjusted by pressing the up and down arrows and using the field key to change the
digit to be edited. UL Gain Cntrl: is the label for the Hub Gain control. Changes made here are
NOT in real time, due to the digitally controlled attenuator. To change the Microcell Gain control,
press the Item Key to access that menu item. Once there, to change the gain, simply use the Field
Key to select the digit and the UP and DOWN keys to alter the values. Once the desired value is
displayed, that menu screen MUST be changed (by pressing the ITEM or MENU key) in order for
the change to take effect. DL# Pwr Cntrl: is the label for the gain control of the PA. Once the
desired value is displayed, that menu screen MUST be changed (by pressing the MENU key) in
order for the change to take affect remotely. Due to network latency, and control setting delay, it
may take up to 15 minutes to change the display. To exit this set of menus, press the MENU KEY.
If no remote detected, the up link gain control can still be adjusted by pressing the ITEM key to
advance from the no remotes on line screen to the appropriate up link gain control. Note: If there is
too little or no signal strength a menu screen will appear to alert the user of the fact and prohibit
him from changing the DL Gain on ANY remotes. You can also set the peak power limit here. The
default is 34, which will prevent the power out of the PA to exceed 34 dBm.
TX 1.9Bse Pwr: XXXX Value in dB corresponding to Power from Base Station to Hub
TX 1.9Lzr Pwr: XXXX Value in dB representing power to the lasers during downlink
AND / OR
TX 800Bse Pwr: XXXX Value in dB corresponding to Power from Base Station to Hub
TX 800Lzr Pwr: XXXX Value in dB representing power to the lasers during downlink
UL Gain # dB: XXXX Value in dB corresponding to the signal strength from
Microcell to the Hub
DL # Pwr dB: XXXX The approximate power in dB the PA is radiating at R#
DL # Peak Pwr: XXXX The Peak power setting for the R#
C. More Menus
By selecting ‘yes’ at the prompt the user will have access to the following Menus. If not,
the menuing will loop back to the ‘Control Menu’.