Operator's Manual

CI Wireless Inc. Installation of the CDR812
MirrorCell Select CDR812 Manual
Rev. X1 7-17
B, C = 0 means the absence of voltage is OK
B, C = 1 means the presence of voltage is OK
7.10 Configuration for MEM Setup
In order to use the MirrorCell Element Manager (MEM) certain parameters must be
adjusted for proper communications between the MEM and the repeater. Follow these
steps to configure the repeater.
1. Turn on power to the repeater.
2. Login to the repeater using a read-and-write password.
3. Set the address code to blank. This will disable the sending of alarms to the MEM.
The MEM will configure the correct address.
SET ASC <enter>
4. Set the communications type to DataCall/modem connection.
SET DEV DTC <enter>
5. If necessary, set the MEM to Repeater password. This information must be
forwarded to the person doing the MEM installation.
SET ORP [password] <enter>
6. The repeater is now set-up for MEM operation.