User's Manual
CI Wireless Inc. 1211 Ira E Woods Ave 57
Tel: 817 416 0583 Grapevine, TX 76051
9.5.3 Down Link Set Up for a GSM System, EkoCel-1.9
Down Link set up for a GSM system is completed with the primary RF carrier. All time
slots are active or filled in on this channel to provide a more accurate power setting.
Display, * Readings/Controls: Adjust base station input power to TX PWR IN Set up
adjustments are always made with a single RF carrier. The following table gives the
system set up levels for a multi carrier system.
For multi-carrier systems adjust this level as follows:
DL RF Input Base Station Input Power Eko-1.9M Eko-1.9R
Controller Screen Tx 1.9Lzr Pwr: Tx 1.9Bse Pwr: DL PA Detect DL PA Detect
or Tx 800Lzr Pwr: Tx 800Bse Pwr: DL # Pwr dB: DL # Pwr dB
Single RF carrier +3 dBm 34 dBm 36 dBm 39 dBm
Two RF carriers -3 dBm 28 dBm 30 dBm 36 dBm
Four RF Carriers -6 dBm 25 dBm 27 dBm 33 dBm
Adjustment to these levels will allow EkoCel to operate to the proper power level as
indicated above.
Display
DL # Pwr dB: Set to XX dBm (set to desired output level in dBm
according to table) Press menu key, unit will self tune
within 10minutes. Typically within 2 – 3 minutes for
Peak Power levels settings.
DL # Peak Pwr: This level should be set no more than 1dB above the
desired maximum output power limit. This feature will
reset the remote to the desired output power should the
power exceed the maimmum output power limit.
Note: # - indicates remote under setup.