User's Manual

CI Wireless Inc. 1211 Ira E Woods Ave 46
Tel: 817 416 0583 Grapevine, TX 76051
G. Set New Password
Only the supervisor’s password has access to this feature also. While it is possible to
access this menu from the Microcell unit, the changes made will be reset through to the
network standard within 20 seconds. This menu is only functional at the hub. The
following are preset passwords: Supervisor - 21314, Tech 1 - 11311, Tech 2 - 11312,
Tech 3 - 11313, Tech 4 - 1000
H. Remote Alarms Reset
To reset specific Microcell’s alarms, press Item to select Microcell then “Yes” or “No”
selections are made by simply press the UP or DOWN. Exit the menu by pressing
MENU. NOTE! Due to network latency it may take up to 20 seconds for the Microcell
alarms to reset.
I. RS 232 PORT MODE
This menu is designed to allow communication to the controller through the RS 232 port.
Here, if ‘none’ is selected, the controller will not acknowledge any incoming data or
commands through the RS 232 port. If ‘Terminal’ is selected the controller will
continually monitor the 232 port for incoming commands. The passwords required to
access the controller through the terminal are the same as the passwords used to access
the controller through the keypad. A Modem will not work if in this state (Terminal
selected). If ‘modem’ is selected, the controller will initialize the modem and wait for it
auto answer. Only after carrier detection takes place will the controller acknowledge
incoming data. A terminal emulator will not work if in this state (modem selected).
J. Exit Menu
“Current Settings: y/n “. Select YES and press MENU to exit all Menuing with current
settings. By pressing the ITEM key, will give access to the TOTAL RESET?: y/n
screen. CAUTION: By selecting YES and pressing menu, WILL RESET ALL Users
defined values to Factory Default, and the Microcell unit will require setting up again.
BE VERY CAREFUL with this menu.
K. AUX Controls Menu
The first prompt will be “More Controls?: y/n “ if yes is selected and the menu key is
pressed, then access to the System settings is given. These settings include: System
Enable, R# System Type , R# RF Channels, R# Batt Backup. If Batt Backup has ‘Yes’
selected then controls for : R# Batt Test Hour and R# Test for Min, will be accessible.
** Will be displayed for the remote master only.